Following
Doc M Regulations
It is important to know that Compliance with Doc M or universal design regulations not only requires precisely designed fittings and components as part of a System solution but also pre-determined room layouts which will offer users comfort to use depending on the location and type of facility in question.
Moreover, this universal solution not only complies with the regulation by meeting and exceeding the needs of everyone because of the flexibility to adapt and remove the products but at the same time will also provide a financial opportunity to maximize occupancy.
The following provides guidance on what is required when designing spaces for hospitality facilities:
Case 1:
Single Toilet Facilities
Where you only have one toilet facility this needs to be a large unisex wheelchair accessible washroom.
• Room size 2200 x 2000mm
• Door must open outwards
• Must be unisex - no longer acceptable to have solely within male or female washroom
WC
• Raised height WC must be 480mm high (to top of seat) with a 750mm projection
• Hidden system helps to improve the aesthetics of the facility
• Wall mounted backrest for WC (only for hidden system)
Washbasin
• Wall hung hand rinse washbasin (height adjustable washbasin bracket for greater flexibility)
• Additional larger washbasin (height adjustable washbasin bracket)
Tap
• Thermostatic mixer tap TMV3 WRAS approved
Grab rails
• 2 x 600mm vertical grab rails by washbasin
• 2 x 600mm vertical grab rails by larger washbasin
• Wall mounted lift up arm support on open side of WC (height adjustable)
• 1 x 600mm horizontal grab rail alongside WC
• 1 x 600mm vertical grab rail above and to the side of drop-down rail
• 450mm horizontal grab rail on the back of the door
DOC M PROFILO SMART SOLUTION
PROFILO SMART SOLUTION PLUS
Case 2:
Multiple Toilet Facilities,
Unisex Wheelchair
Where you have a washroom with more than one toilet you will need a unisex wheelchair accessible washroom by the main washroom.
• Room size 2200 x 1500mm
• Door must open outwards
• Must be unisex
WC
• Raised height WC must be 480mm high (to top of seat) with a 750mm projection
• Hidden system helps to improve the aesthetics of the facility
• Wall mounted backrest for WC (only for hidden system)
Washbasin
• Must have wall hung washbasin (height adjustable washbasin bracket for greater flexibility)
Tap
• Thermostatic mixer tap TMV3 WRAS approved
Grab rails
• 2 x 600mm vertical grab rails by washbasin
• Wall mounted lift up arm support on open side of WC (height adjustable)
• 1 x 600mm horizontal grab rail alongside WC
• 1 x 600mm vertical grab rail above and to the side of drop-down rail
• 450mm horizontal grab rail on the back of the door
DOC M PROFILO SMART SOLUTION
PROFILO SMART SOLUTION PLUS
Case 3:
Hotel Facilities - Bathroom
1 in every 20 rooms must provide for disabled use. Also applies to motels, student accommodation and relative’s accommodation in hospitals (Also known as the 5% Rule).
• Room size 2500 x 2500mm min
• All users should be able to wash or bathe independently or with assistance from others
• A choice of bathroom layout, wherever possible will meet more needs
• Layout should accommodate left and right-hand transfer when there is more than one bathroom
• Floor must be slip-resistant
WC
• Raised height WC must be 480mm high (to top of seat) with a 750mm projection
• Hidden system helps to improve the aesthetics of the facility
• Wall mounted backrest for WC (only for hidden system)
• Wall mounted lift up arms support on both sides of WC, with toilet paper holder.
Washbasin
• Needs to be reached from WC to allow for hand washing (Manual adjustability option available)
• If larger washbasin is required it will have to be recessed (Manual adjustability option available)
Bath
• Bath must be 480mm high to allow for wheelchair transfer
• Bath needs a transfer seat 400mm deep and as wide as the bath
Grab rails
• 2 x 600mm vertical grab rails by washbasin (45cm above the track)
• 1 x 600mm horizontal grab rail alongside WC
• 1 x 600mm vertical grab rail above and to the side of drop-down rail (45cm above the track)
• 450mm horizontal grab rail on back of door
• Angled horizontal grab rail to run alongside bath
DOC M PROFILO SMART SOLUTION
PROFILO SMART SOLUTION PLUS
Case 4:
Hotel Facilities - Shower Room
1 in every 20 rooms must provide for disabled use (Also known as the 5% Rule). Bedrooms deemed wheelchair accessible should have a 50:50 ratio of baths and showers. Also applies to motels, student accommodation and relative’s accommodation in hospitals
• Room size 2500 x 2500mm min
• Half the wheelchair accessible bedrooms should have shower facilities to offer an alternative from baths
• Floor must be slip-resistant
• A shelf should be situated so it can be reached from the shower seat or wheelchair for toiletries
WC
• Raised height WC must be 480mm high (to top of seat) with a 750mm projection
• Hidden system helps to improve the aesthetics of the facility
• Wall mounted backrest for WC (only for hidden system)
• Wall mounted lift up arms support on both sides of WC, with toilet paper holder.
Washbasin
• Needs to be reached from WC to allow for hand washing (Manual adjustability option available)
• If larger washbasin is required it will have to be recessed (Manual adjustability option available)
Shower
• Thermostatic shower with logical and clear markings
• Both fixed head and adjustable shower kit are required (45cm above the track)
• Shower seat with backrest and arm support. Hight and sideways adjustable with especial design 560mm seat projection. (no need for 2 x hinged support arm on open sides of tip up shower seat if shower seat has arm supports)
Grab rails
• 2 x 600mm vertical grab rails by washbasin (Plus option 45cm above the track)
• 1 x 600mm horizontal grab rail alongside WC
• 1 x 600mm vertical grab rail above and to the side of drop-down rail (45cm above the track)
• Horizontal grab rail alongside shower seat 1 x 600mm
• 450mm horizontal grab rail on back of door
• Retractable privacy curtain
DOC M PROFILO SMART SOLUTION
PROFILO SMART SOLUTION PLUS
Case 5:
Public Shower Facilities
If you are offering shower facilities in a sports centre, swimming pool or health and leisure centre at least one should be wheelchair accessible.
• Layout must allow privacy and space for assisted care
• Controls should be positioned between 750 and 1000mm from the floor
• Facility must have slip-resistant flooring
• Thermostatic shower with logical and clear markings
• Both fixed head and adjustable shower kit are required
Shower
• Thermostatic shower with logical and clear markings
• Both fixed head and adjustable shower kit are required
• Shower seat with backrest and arm support. Highway adjustable with especial design 560mm seat projection. (no need for 2 x hinged support arm on open sides of tip-up shower seat if shower seat has arm supports)
Grab rails
• 600mm vertical grab rail by shower rail
• 460mm vertical rail with sliding shower handset
• 2 x hinged support arms by tip-up shower seat if not already incorporated within the shower seat.
• 600mm horizontal grab rail alongside shower seat
• 600mm horizontal grab rail outside shower
• 450mm horizontal grab rail on back of door
• Shower curtain and rail
DOC M PROFILO SMART SOLUTION